Brandenburg Product Catalogue
2481
Series Data Sheet
High power photomultiplier PSU
Output Voltage up to 1.8 kV
Power Rating up to 54 Watts
![]() |
| Features |
|---|
Mains
input version (115V or 230V) DC to DC version (24V nominal input) Positive and negative versions Full performance over wide output
range Voltage & current monitor outputs Very low output ripple and drift Remote voltage programming (0 to
10V) Protected against overload & short
circuit Active voltage and current limit |
| Description |
|---|
|
This series of high power modules has been specially designed for distributed power systems where multiple PM tube arrays are being used. There are both line powered and DC to DC versions available with a positive or negative high voltage output. The use of high-stability components in the feedback system ensures a low temperature coefficient and good long and short term drift. The supplies are coated against the effects of excess humidity and mechanical stress and are housed within a metal enclosure providing excellent screening. The output voltage may be controlled from less than 20V up to maximum output by either an external control voltage or a user accessible potentiometer. Also provided is a precision reference output for applications where an external potentiometer would be preferable. Pre-scaled buffered monitor outputs are provided for both output current and voltage monitoring. Active voltage clamp and current limit are also provided (adjusted via front panel potentiometers) to ensure against accidental damage to PM tubes through excessive voltage. |
| Ordering Information | ||||
|---|---|---|---|---|
| Input Voltage Nominal | Output Voltage Range | Output Current | Polarity | Order Code |
| 115 or 230V ac | 20V to 1.8kV | 30mA | Positive | On Request |
| 115 or 230V ac | -20V to -1.8kV | 30mA | Negative | On Request |
| 24V dc | 20V to 1.8kV | 30mA | Positive | 2481-102 |
| 24V dc | -20V to -1.8kV | 30mA | Negative | 2481-202 |
| Electrical Specification 2481-101 & 2481-201 |
|---|
| AC supply input voltage | 90V to 130V on 115V range and 180V to 260V on 230V range |
| AC supply frequency range | 47Hz to 63Hz |
| Efficiency at full load | 65% typ |
| Output voltage range | <20V to 1.8kV dc |
| Output polarity | Positive or negative versions , see ordering information |
| Output current | 30mA |
| Control of output Voltage | 0 to +10V control voltage varies output from 0% to 100% rated output, input impedance 1Mohm |
| Output ripple/ LF noise | Ripple 7mV pk-pk and LF noise 10mV pk-pk |
| Line regulation | 20ppm (max) for +/-10% mains voltage change |
| Load regulation | 50ppm (max) for 0% to 100% and 100% to 0% load change |
| Output drift | 15ppm per hour 50ppm in any 8 hour period, after 30 min. warm-up |
| Temperature coefficient | 50ppm / deg.C |
| Fixed reference output | +10V +/-0.5% temperature coefficient 50ppm / deg.C |
| Variable reference output | 0 to +10V (multi-turn potentiometer) |
| Current & voltage monitor | 10V for 100% of rated output, accuracy +/-1%, source impedance 10kohm |
| Protection | Protection
against overload, short circuit and flashover. Voltage: Active voltage limit, set via front panel multi-turn potentiometer (range <5% to >105%) Current: Active current limit, set via front panel multi-turn potentiometer (range <5% to >105%) (Set point check outputs for both output voltage and current limit are provided, these are scaled 0V to 10.5V for 0% to 105%, +/-1%, source impedance 10kohm) |
| Safety | Designed to meet UL1950 and EN 61010 |
| Mechanical Specification 2481-101 & 2481-201 |
|---|
|
Dimensions
|
Width:
84mm (3.30")
Height: 120mm (4.72") Depth: 211mm (8.3") |
|
Fixings
|
4
off M4 x 8mm tapped bushes
|
|
Weight
|
1.7kg
(3.8lb) approx.
|
|
Connections
| |
|---|---|
|
Mains
|
IEC
3-pin mains connector
|
|
HV
Output
|
BNC
type Coaxial MHV connector, mating half supplied as an optional extra
(Brandenburg pt: PLC021-000, Radiall pt: R316011/UG932/V28000).
|
|
Earth
|
M4
stud, internally grounded.
|
|
Control
|
Molex
10 way (plug type: 39-01-3109)
|
| Electrical Specification 2481-102 & 2481-202 |
|---|
| Input voltage range | 24V +/-5% |
| Input current | 2A nominal |
| Efficiency at full load | 80% typ |
| Output voltage range | <20V to 1.8kV dc |
| Output polarity | Positive or negative versions , see ordering information |
| Output current | 30mA |
| Control of output Voltage | 0 to +10V control voltage varies output from 0% to 100% rated output, input impedance 1Mohm |
| Output ripple/ LF noise | Ripple 7mV pk-pk and LF noise 10mV pk-pk |
| Line regulation | 20ppm (max) for +/-5% change in input Voltage |
| Load regulation | 50ppm (max) for 0% to 100% and 100% to 0% load change |
| Output drift | 15ppm per hour 50ppm in any 8 hour period, after 30 min. warm-up |
| Temperature coefficient | 50ppm / deg.C |
| Fixed reference output | +10V +/-0.5% temperature coefficient 50ppm / deg.C |
| Variable reference output | 0 to +10V (multi-turn potentiometer) |
| Current & voltage monitor | 10V for 100% of rated output, accuracy +/-1%, source impedance 10kohm |
| Protection | Protection
against overload, short circuit and flashover. Voltage: Active voltage limit, set via front panel multi-turn potentiometer (range <5% to >105%) Current: Active current limit, set via front panel multi-turn potentiometer (range <5% to >105%) (Set point check outputs for both output voltage and current limit are provided, these are scaled 0V to 10.5V for 0% to 105%, +/-1%, source impedance 10kohm) |
| Safety | Designed to meet UL1950 and EN 61010 |
| Environmental Specification 2481-102 & 2481-202 |
|---|
| Operating temperature range | -10 to +50 deg.C |
| Storage temperature range | -20 to +75 deg.C |
| Circuit coated for protection against humidity |
| Mechanical Specification 2481-102 & 2481-202 |
|---|
| Dimensions | Width
38mm (1.5") Height 120mm (4.72") Depth 211mm (8.3") |
| Fixings | 4 off M4 x 8mm tapped bushes |
| Weight | 1kg (2.2lb) approx. |
| Connections | |
|---|---|
| 24V dc supply | 4 way Molex connector (plug type: 39-01-3049) |
| HV Output | BNC type Coaxial MHV connector, mating half supplied as an optional extra (Brandenburg pt: PLC021-000, Radiall pt: R316011/UG932/V28000). |
| Earth | M4 stud, internally grounded. |
| Control | Molex 10 way (plug type: 39-01-3109) |