Brandendurg 139 Series Data Sheet
Digital High Voltage Meter
Dual Range 0-20kV, 0-40kV DC
Positive and Negative Reading

Model 139 Meter

Features

Direct reading digital HV meter
3 1/2 digit LCD display
Extremely high input impedance
Positive and negative reading without switching
Accuracy better than 0.25% at 20kV
Battery operated
Precision output for recorder
High voltage probe supplied
Rugged construction with metal case

Description

In this direct reading digital High Voltage meter, a fully encapsulated input potential divider chain, using precision HV resistors of extremely high value, feeds a digital voltmeter module of high input resistance. Two ranges are provided: 0-20kV with 10V resolution and 0-40kV with 100V resolution. This gives a dc voltage measuring instrument with an accuracy of better than 0.25% which loads the circuit under test by less than 2ľA at the highest input voltage.

The meter provides accurate, high resolution measurement of high voltages over a wide range of values, with extremely low circuit loading. Positive and negative voltages may be measured without the need for switching. The digital meter Model 139 offers greater accuracy and higher resolution than the analogue meters Models 88 and 109, but with a higher current drain on the circuit under test.

The HV meter is battery operated and has a single control: a 20kV/40kV range selector switch with an OFF position. The DVM module itself incorporates low-battery indication. A precision recorder output is provided at 10mV per kV of input. The meter may be angled for convenience of reading when on a bench, and is housed in a metal case. The HV connection is made to a fully insulated socket with moulded polythene shroud. A mating screw-in connector with 2m lead, fitted with a 40kV hand-held probe, is supplied as standard. Other connectors are available.


CAUTION
Great care must be taken when making measurements in high voltage circuits. ALWAYS ensure that the HV Return terminal of the meter is grounded. DO NOT use hand-held probes on supplies that are potentially lethal.

Ordering
Imformation
Meter ranges Resolution Input resistance Ordering Code
0 to +/-20kV dc
and 0 to +/-40kV dc
10V
100V
30,000Mohm
(both ranges)
139
Please note that there is a minimum order quantity of 5 pieces on this product

 

Electrical
Specification
Voltage ranges 0 to +/-20kV dc and 0 to +/-40kV dc (switch selected)
Resolution 10V on 20kV range and 100V on 40kV range
Accuracy 0.25% at 20kV (spot) at 23 deg.C (additional 0.025% per 1kV for voltages < or > 20kV)
Input resistance30,000MW
Stability Better than 0.3% over 1 year
Input current Less than 2ľA drawn from circuit under test at maximum voltage
Polarity Positive or negative, auto reading
Protection Circuits proected against damage by external arcing, flashovers etc.
Recorder output 10mV per kV Accuracy: ¤1.5% at 40kV
Initial offset: <0.2mV
Thermal drift: < 150 ppm per deg.C
Long term drift: <0.5% over 1 year
Source/sink capability up to 100ľA
Controls OFF / 20kV / 40kV switch
Battery type One PP6 (IEC No.6F50-2. NEDA No. 1602)
Battery life Approx. 1000 hours operation
Battery check Automatic: BAT shown on LCD display when battery is low

Environmental
Specification
Operating temperature range 0 to +50 deg.C
Storage temperature range -20 to +65 deg.C
All high voltage components are fully encapsulated for protection against humidity.

Mechanical
Specification
Dimensions 215 x 60 x 185 mm (plus connectors)
Weight 1.35 kg including battery and HV cable
Connections HV input:Recessed terminal to accept Brandenburg screwed connector. Mating connector with 2m HV cable and hand held 40kV probe supplied.
HV return: 4 mm screwed terminal
Recorder: 4 mm sockets
Battery access By removal of cover plate at the rear of the instrument